Basic Info.
Voltage
Low and Medium Voltage Cable
Insulation Material
XLPE/PE
Material Shape
Round Wire
Wire Core Material
Aluminum
Certification
ISO, CCC, CE
Name
ABC Triplex Shrimp/Prawn
Company Type
Manufacturer
Transport Package
Drum/Container
Product Description
Cable Price list 0.6kv/1kv Aerial Bunched Cable ABC Triplex Shrimp/Prawn
APPLICATIONS
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
SPECIFICATIONS
Huatong's triplex service drop cable meets or exceeds the following ASTM specifications:
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR).
• B-399 Stranded 6201-T81 Aluminum Alloy Conductors.
• B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
Huatong's triplex service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
CONSTRUCTION
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or crosslinked polyethylene (XLP). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.
Triplex Service Drop | | | | | | | | | |
Code* Word | Phase Conductor | Bare Neutral Messenger | Weight per 1000 ft. (lbs.) | Allowable Ampacities+ |
Size (AWG) | Strand- ing | Insul. Thick. (mils) | Equiv. Dia. (AWG)++ | Size++ (kcmil) | Strand-ing | Rated Strength (lbs.) | XLP | POLY | XLP | POLY |
6201 ALLOY NEUTRAL-MESSENGER |
Minex | 6 | 1 | 45 | 6 | 30.58 | 7 | 1110 | 101 | 101 | 85 | 70 |
Hippa | 6 | 7 | 45 | 6 | 30.58 | 7 | 1110 | 107 | 107 | 85 | 70 |
Prawn | 4 | 1 | 45 | 4 | 48.69 | 7 | 1760 | 152 | 152 | 115 | 90 |
Bamacle | 4 | 7 | 45 | 4 | 48.69 | 7 | 1760 | 160 | 160 | 115 | 90 |
Shrimp | 2 | 7 | 45 | 2 | 77.47 | 7 | 2800 | 243 | 243 | 150 | 120 |
Gammarus | 1/0 | 7 | 60 | 1/0 | 123.3 | 7 | 4460 | 390 | 390 | 205 | 160 |
Leda | 1/0 | 9 | 60 | 1/0 | 123.3 | 7 | 4460 | 384 | 384 | 205 | 160 |
Dungenese | 2/0 | 7 | 60 | 2/0 | 155.4 | 7 | 5390 | 483 | 483 | 235 | 185 |
Cyclops | 2/0 | 11 | 60 | 2/0 | 155.4 | 7 | 5390 | 474 | 474 | 235 | 185 |
Flustra | 3/0 | 17 | 60 | 3/0 | 195.7 | 7 | 6790 | 587 | 587 | 275 | 215 |
Lepas | 4/0 | 18 | 60 | 4/0 | 246.9 | 7 | 8560 | 728 | 728 | 315 | 245 |
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP). |
+ Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC;emissivity 0.9; 2 ft./sec. wind in sun. |
Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201. |
Code* Word | Phase Conductor | Bare Neutral Messenger | Weight per 1000 ft. (lbs.) | Allowable Ampacities+ |
Size (AWG or kcmil) | Strand- ing | Insul. Thick. (mils) | Size (AWG or kcmil) | Strand-ing | Rated Strength (lbs.) | XLP | POLY | XLP | POLY |
AAC NEUTRAL-MESSENGER |
Patella | 6 | 7 | 45 | 6 | 7 | 563 | 103 | 103 | 85 | 70 |
Oyster | 4 | 7 | 45 | 4 | 7 | 881 | 154 | 154 | 115 | 90 |
Clam | 2 | 7 | 45 | 2 | 7 | 1350 | 233 | 233 | 150 | 120 |
Murex | 1/0 | 7 | 60 | 1/0 | 7 | 1990 | 374 | 374 | 205 | 160 |
Purpura | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 368 | 368 | 205 | 160 |
Nassa | 2/0 | 7 | 60 | 2/0 | 7 | 2510 | 462 | 462 | 235 | 185 |
Melita | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 562 | 562 | 275 | 215 |
Portunus | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 696 | 696 | 315 | 245 |
Nannynose | 336.4 | 19 | 80 | 336.4 | 19 | 6146 | 1118 | 1118 | 420 | 325 |
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP). |
+ Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC;emissivity 0.9; 2 ft./sec. wind in sun. |
Code* Word | Phase Conductor | Bare Neutral Messenger | Weight per 1000 ft. (lbs.) | Allowable Ampacities+ |
Size (AWG or kcmil) | Strand- ing | Insul. Thick. (mils) | Size (AWG or kcmil) | Strand-ing | Rated Strength (lbs.) | XLP | POLY | XLP | POLY |
ACSR NEUTRAL-MESSENGER |
Paludina | 6 | 1 | 45 | 6 | 6/1 | 1190 | 109 | 109 | 85 | 70 |
Voluta | 6 | 7 | 45 | 6 | 6/1 | 1190 | 114 | 114 | 85 | 70 |
Whelk | 4 | 1 | 45 | 4 | 6/1 | 1860 | | 164 | 115 | 90 |
Periwinkle | 4 | 7 | 45 | 4 | 6/1 | 1860 | 172 | 172 | 115 | 90 |
Conch | 2 | 7 | 45 | 2 | 6/1 | 2850 | 262 | 262 | 150 | 120 |
Neritina | 1/0 | 7 | 60 | 1/0 | 6/1 | 4380 | 420 | 420 | 205 | 160 |
Cenia | 1/0 | 9 | 60 | 1/0 | 6/1 | 4380 | 414 | 414 | 205 | 160 |
Runcina | 2/0 | 7 | 60 | 2/0 | 6/1 | 5310 | 520 | 520 | 235 | 185 |
Triton | 2/0 | 11 | 60 | 2/0 | 6/1 | 5310 | 512 | 512 | 235 | 185 |
Mursia | 3/0 | 17 | 60 | 3/0 | 6/1 | 6620 | 635 | 635 | 275 | 215 |
Zuzara | 4/0 | 18 | 60 | 4/0 | 6/1 | 8350 | 789 | 789 | 315 | 245 |
Limpet | 336.4 | 19 | 80 | 336.4 | 18/1 | 8680 | 1167 | 1167 | 420 | 325 |
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP). |
+ Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC;emissivity 0.9; 2 ft./sec. wind in sun. |
Code* Word | Phase Conductor | Bare Neutral Messenger | Weight per 1000 ft. (lbs.) | Allowable Ampacities+ |
Size (AWG) | Strand- ing | Insul. Thick. (mils) | Size (AWG) | Strand-ing | Rated Strength (lbs.) | XLP | POLY | XLP | POLY |
ACSR REDUCED NEUTRAL-MESSENGER |
Scallop | 4 | 1 | 45 | 6 | 6/1 | 1190 | | 142 | 115 | 90 |
Strombus | 4 | 7 | 45 | 6 | 6/1 | 1190 | 151 | 151 | 115 | 90 |
Cockle | 2 | 7 | 45 | 4 | 6/1 | 1860 | 228 | 228 | 150 | 120 |
Janthina | 1/0 | 7 | 60 | 2 | 6/1 | 2853 | 366 | 366 | 205 | 160 |
Ranella | 1/0 | 9 | 60 | 2 | 6/1 | 2853 | 360 | 360 | 205 | 160 |
Cavolinia | 2/0 | 7 | 60 | 1 | 6/1 | 3550 | 453 | 453 | 235 | 185 |
Clio | 2/0 | 11 | 60 | 1 | 6/1 | 3550 | 444 | 444 | 235 | 185 |
Aega | 3/0 | 17 | 60 | 1/0 | 6/1 | 4380 | 549 | 549 | 275 | 215 |
Cerapus | 4/0 | 18 | 60 | 2/0 | 6/1 | 5310 | 681 | 681 | 315 | 245 |
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP). |
+ Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC;emissivity 0.9; 2 ft./sec. wind in sun. |
Code* Word | Phase Conductor | Bare Neutral Messenger | Weight per 1000 ft. (lbs.) | Allowable Ampacities+ |
Size (AWG) | Strand- ing | Insul. Thick. (mils) | Equiv. Dia. (AWG)++ | Size (kcmil) | Strand-ing | Rated Strength (lbs.) | XLP | POLY | XLP | POLY |
6201 ALLOY REDUCED NEUTRAL-MESSENGER |
Artemia | 4 | 1 | 45 | 6 | 30.58 | 7 | 1110 | 135 | 135 | 115 | 90 |
Crab | 4 | 7 | 45 | 6 | 30.58 | 7 | 1110 | 143 | 143 | 115 | 90 |
Solaster | 2 | 7 | 45 | 4 | 48.69 | 7 | 1760 | 216 | 216 | 150 | 120 |
Sandcrab | 1/0 | 7 | 60 | 2 | 77.47 | 7 | 2800 | 347 | 347 | 205 | 160 |
Echinus | 1/0 | 9 | 60 | 2 | 77.47 | 7 | 2800 | 341 | 341 | 205 | 160 |
Fulgar | 3/0 | 17 | 60 | 1/0 | 123.3 | 7 | 4460 | 519 | 519 | 275 | 215 |
Arca | 4/0 | 18 | 60 | 2/0 | 155.4 | 7 | 5390 | 643 | 643 | 315 | 245 |
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP). |
+ Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC;emissivity 0.9; 2 ft./sec. wind in sun. |
Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201. |
Address:
Shijiawan Industrial Estate, Guxian Town, Yanshi City, Luoyang, Henan, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001, ISO 14001
Company Introduction:
Huatong Cable Inc. has made outstanding contribution to STATE GRID, China SOUTH POWER GRID and the construction of domestic and foreign power market since foundation in 1993. The honors should be attributed to more than 20 years of constant R&D, market service and strong will.
Huatong Cable Inc. has set up overhead conductor division, power cable division and division of wire and cable for equipment. The division respectively takes charge of manufacture and marketing of overhead conductor, power cable and wire and cable for equipment. In 2002, our company set up the cable industry design and technology R&D department, providing technical support for product design and production. Our company makes independent innovation, and seeks cooperation with academic institutions including Shanghai Electric Cable Research Institute and China Electric Power Research Institute so as to meet the customized demands of customers and production needs of special cable. Now our company owns 25 exclusive rights to use trademark registered at home and abroad and 14 independent intellectual property patents. ACSR-720/50 aluminum cable steel reinforced has passed the technical appraisal of China Electricity Council. 500KV or above extra-high voltage conductor was put into production, came into service and had good operation record.
In 2013, Huatong Brand was awarded WELL KNOWN MARK OF China by the Trademark Office of the State Administration of Industry and Commerce, enjoying a high reputation in domestic market. The honor and legal status reflect the recognition of customers and support of the State Administration of Industry and Commerce. It is the only enterprise in cable industry in Henan that was awarded WELL KNOWN MARK OF China and Huatong brand will serve the society in the future.