Gold Member Since 2016
Audited Supplier
Huatong Cable Inc.

ACSR Conductor, AAC Conductor, Acar Conductor manufacturer / supplier in China, offering Aluminum Conductor Line Overhead Conductor ACSR Acar AAC AAAC, LV and Mv Single/Duplex/Triplex Aluminium Covered Conductor, Telecommunication Low Smoke Halogen Free Tfl DC Power Cable and so on.

(/ )

Supplier Homepage Product AAC Aluminum Conductor Line Overhead Conductor ACSR Acar AAC AAAC

Aluminum Conductor Line Overhead Conductor ACSR Acar AAC AAAC

FOB Price: US $1,000 / Meter
Min. Order: 1,000 Meters
Min. Order FOB Price
1,000 Meters US $1,000/ Meter
Get Latest Price
Port: Qingdao, China
Production Capacity: 5000tons/Month
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Product Catalog
AAC
10 Products
Content
Product Image
Product Name
FOB Price
Port
Payment Terms
Product Package
Product Attribute
Product Table
Basic Info
  • Model NO.: AAC conducotor
  • Conductor Type: Stranded
  • Conductor Material: Aluminum
  • Insulation Material: Bare
  • Certification: ISO9001, CE, CCC, RoHS, VDE
  • Color: as Per Your Request
  • ACSR Voltage: LV. Mv. Hv
  • Transport Package: Wooden /Steel Wooden /Steel Package
  • Origin: in China
  • Type: Bare
  • Application: Overhead
  • Sheath Material: No
  • Material Shape: Round Wire
  • Brand: Huatong
  • Sample: as Per Your Customers′ Request
  • Trademark: Huatong
  • Specification: 10-800mm
  • HS Code: 76149000
Product Description
Aluminum Conductor Line Overhead Conductor ACSR Acar AAC AAAC
aluminium bare conductors
StandardsIEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110
CertificateISO 9001 and ISO 14001. CE ,SONCAP
TypeAAC, AAAC, ACSR, AACSR&ACAR conductor
 
 
AAC, AAAC, ACSR, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels.
Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.
1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM
(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.
Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.
Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
Packing:
Standard export wooden drums
 echnical details
 AAC Technical Characteristics Based on Standard DIN 48201 / DIN EN50182
  
Code numberAreaNumber of wiresWire     diameterConductor diameterLinear massRated strengthD.C. resistance at 20oC
mm2No.mmmmkg/kmkNΩ/km
1615.971.75.143.43.021.7986
2524.272.16.366.34.361.1787
3534.472.57.593.96.010.8317
5049.5739135.28.410.5776
5048.3191.89132.98.940.5944
7065.8192.110.5180.911.850.4367
9593.3192.512.5256.316.320.3081
120117192.814321.519.890.2456
150147.1372.2515.8405.726.480.196
185181.6372.517.5500.931.780.1588
240242.5612.2520.3671.143.660.1193
300299.4612.522.5828.552.40.0966

 
ACSR Technical Characteristics Based on Standard BS 215-2   
 
Code nameNominal aluminium areaStranding and wire     diameterSectional area of aluminiumTotal sectional areaApprox. overall diameterApprox. massCalculated D.C. resistance at 20oCCalculated breaking load
AlSteel
mm2No./mmmm2mm2mmkg/kmΩ/kmkN
RABBIT506/3.351/3.3552.8861.710.052140.542618.35
DOG1006/4.727/1.57105118.514.153940.273332.7
WOLF15030/2.597/2.59158.1194.918.137260.182869.2
DINGO15018/3.351/3.35158.7167.516.755060.181535.7
LYNX17530/2.797/2.79183.4226.219.538420.157679.8
ZEBRA40054/3.187/3.18428.9484.528.6216210.0674131.9

 
 
 AAAC Technical Characteristics Based on Standard BS 3242  
 
Code nameNominal aluminium areaStranding and wire     diameterSectional areaApprox. overall diameterApprox. massCalculated D.C. resistance at 20oCCalculated breaking load
mm2No./mmmm2mmkg/kmΩ/kmkN
ALMOND257/2.3430.17.02821.0948.44
CEDAR307/2.5435.477.62970.92819.94
FIR407/2.9547.848.851310.68813.4
HAZEL507/3.3059.879.91640.549816.8
OAK1007/4.65118.913.953250.276933.3
ASH15019/3.48180.717.44970.18350.65
ELM17519/3.7621118.85800.156859.1
UPAS30037/3.53362.124.719970.09155101.5



 