Gold Member Since 2016
Audited Supplier
Huatong Cable Inc.

ABC Cable, Overhead ABC Cable, PVC/XLPE Insulated manufacturer / supplier in China, offering Al/XLPE 0.6/1kv Overhead ABC Cable, LV and Mv Single/Duplex/Triplex Aluminium Covered Conductor, Telecommunication Low Smoke Halogen Free Tfl DC Power Cable and so on.

(/ )

Supplier Homepage Product 0.6/1 KV ABC Cable Al/XLPE 0.6/1kv Overhead ABC Cable

Al/XLPE 0.6/1kv Overhead ABC Cable

FOB Price: US $1,000 / Meter
Min. Order: 1,000 Meters
Min. Order FOB Price
1,000 Meters US $1,000/ Meter
Get Latest Price
Production Capacity: 5000tons /Month
Transport Package: All Wooden, Steel Wooden or Steel Package
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: ABC cable
  • Conductor Type: Stranded
  • Conductor Material: Aluminum
  • Insulation Material: XLPE
  • Range of Application: Overhead
  • Brand: Huatong
  • Color: as Per Your Customers ′ Request
  • Trademark: Huatong
  • HS Code: 8544492100
  • Type: Insulated
  • Application: Overhead, Underground
  • Sheath Material: No
  • Material Shape: Round Wire
  • Certification: ISO9001, CE, CCC, RoHS
  • Voltage: LV. Mv. Hv
  • Insulated Materials: PVC/PE/XLPE
  • Origin: China
Product Description

0.6/1kv ABC cable duplex/triplex/quadruplex service drop cable aerial bundled cable

I:Applications:

Primarily used for overheard service applications such as street lighting,outdoor lighting,and temporary service for construction.To be used at votage of 600V phase-to-phase and conductor temperatures not to exceed 75ºC for polyethylene insulated conductors or 90ºC for crossliked polythylene(XLPE)insulated conductors.

II: Service drop cable meets or exceeds the following specifications:

1.Aluminum Wire,1350-H19 for Electrical Purposes.

2.Aluminum Conductor,Concentric-Lay-Stranded.

3.Aluminum Conductor,Concentric-Lay-Stranded.Coated Steel Reinforced(ACSR).

4. Concentric-Lay-Stranded 6201-T81 Conductors.

5. Service drop cable meets or exceeds all applicable requirement of ANSI/ICEA S-76-474.

Standards:
B-230 Aluminum Wire 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.
There is a lot of debate still going on as to whether copper is better for electrical purposes or aluminum. If price was not a critical factor, most would suggest going in for silver as it is said to be the best conductor of electricity but has a low strength. However, when it comes to electrical wiring, price is a factor, as is efficiency.


Triplex Aluminum Service Drop Cable

Code Word
Phase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+
Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Size (kcmil)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLY
AAAC 6201 ALLOY FULL NEUTRAL MESSENGER
Minex6145630.58711101011018570
Hippa6745630.58711101071078570
Prawn4145448.697176015215211590
Barnacle4745448.697176016016011590
Shrimp2745277.4772800243243150120
Gammarus1/07601/0123.374460390390205160
Leda1/09601/0123.374460384384205160
Dunganese2/07602/0155.475390474474235185
Cyclops2/011602/0155.475390474474235185
Flustra3/017603/0195.776790587587275215
Lepas4/018604/0246.978560728728315245
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.
 

Code Word
Phase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+
Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Size (kcmil)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLY
AAAC 6201 ALLOY REDUCED NEUTRAL MESSANGER
Artemia4145630.587111013513511590
Crab4745630.587111014314311590
Solaster2745448.6971760216216150120
Sandcrab1/0760277.4772800347347205160
Echinus1/0960277.4772800341341205160
Crayfish2/07/w60 mls2/0--72510485.8455.3235 Amps185 Amps
Sipho2/07/w60 mls2/0--72510485.8455.3235 Amps185 Amps
Fulgar3/017601/0123.374460519519275215
Arca4/018602/0155.475390643643315245
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

 
 

Code Word
Phase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+...............
Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLY
AAC NEUTRAL-MESSENGER
Haiotis67/w45 mls67563109.1101.685 Amps70 Amps
Patella6745675631031038570
Fusus47/w45 mls47881161.8151.7115 Amps90 Amps
Oyster47454788115415411590
Clam2745271350233233150120
Murex1/07601/071990374374205160
Purpura1/09601/071990368368205160
Nassa2/07602/072510462462235185
Melita3/017603/0193310562562275215
Portunus4/018604/0194020696696315245
Nannynose336.41980336.419614611181118420325
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.
 

Code Word
Phase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+
Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLY
ASCR NEUTRAL-MESSENGER
Paludina614566/111901091098570
Voluta674566/111901141148670
Whelk414546/11860--16411590
Periwinkle474546/1186017217211590
Conch27601/06/14380420420205160
Neritina1/07601/06/14380420420205160
Cenia1/09601/06/14380414414205160
Runcina2/07602/06/15310520520235185
Triton2/011602/06/15310512512235185
Mursia3/017603/06/16620635635275215
Zuzara4/018604/06/18350789789315245
Limpet336.41980336.418/1868011671167420325
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.
 

Code Word
Phase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+
Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLY
ASCR REDUCED NEUTRAL-MESSENGER
Scallop414566/11190--14211590
Strombus474566/1119015115111590
Cockle274546/11190220220150120
Janthina1/076026/12853366366205160
Ranella1/096026/12853360360205160
Cavolinia2/076016/13550453453235185
Clio2/0116016/13550444444235185
Sanddollar3/019/w60 mls1/06/14380565552275 Amps215 Amps
Aega3/017601/06/14380549549275215
Cuttlefish4/019/w60 mls2/06/15310699684315 Amps245 Amps
Cerapus4/018602/06/15310681681315245
Cowery336.41980 mls336/418/1868012091167420 Amps325 Amps
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.
Al/XLPE 0.6/1kv Overhead ABC Cable

 
You Might Also Like
Send your message to this supplier
Avatar
Ms. Carrey Guo
sales manager
*From:
To: Ms. Carrey Guo
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now