Gold Member Since 2016
Audited Supplier
Huatong Cable Inc.

ABC Cable, Aerial Bundled Cable, PVC/XLPE Insulated manufacturer / supplier in China, offering 0.6/1kv Aluminiun Core Overhead Line ABC Cable, Aluminum Service Drop, Triplex Service Drop, LV and Mv Single/Duplex/Triplex Aluminium Covered Conductor, Telecommunication Low Smoke Halogen Free Tfl DC Power Cable and so on.

(/ )

Supplier Homepage Product 0.6/1 KV ABC Cable 0.6/1kv Aluminiun Core Overhead Line ABC Cable, Aluminum Service Drop, Triplex Service Drop

0.6/1kv Aluminiun Core Overhead Line ABC Cable, Aluminum Service Drop, Triplex Service Drop

FOB Price: US $1,000 / Meter
Min. Order: 1,000 Meters
Min. Order FOB Price
1,000 Meters US $1,000/ Meter
Get Latest Price
Port: Qingdao, China
Production Capacity: 5000tons /Month
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: aluminum service drop
  • Conductor Type: Stranded
  • Conductor Material: Aluminum
  • Insulation Material: XLPE
  • Range of Application: Overhead
  • Brand: Huatong
  • Color: as Per Your Customers ′ Request
  • Trademark: Huatong
  • Origin: China
  • Type: Insulated
  • Application: Overhead, Underground
  • Sheath Material: No
  • Material Shape: Round Wire
  • Certification: ISO9001, CE, CCC, RoHS
  • Voltage: LV. Mv. Hv
  • Insulated Materials: PVC/PE/XLPE
  • Transport Package: All Wooden, Steel Wooden or Steel Package
  • HS Code: 8544492100
Product Description
Aerial Bundled Cable, ABC Cable, Overhead cable,ASTM, BS, NFC, IEC, DIN Standard

Triplex Aluminum Service Drop Cable

Code Word
Phase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+
Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Size (kcmil)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLY
AAAC 6201 ALLOY FULL NEUTRAL MESSENGER
Minex6145630.58711101011018570
Hippa6745630.58711101071078570
Prawn4145448.697176015215211590
Barnacle4745448.697176016016011590
Shrimp2745277.4772800243243150120
Gammarus1/07601/0123.374460390390205160
Leda1/09601/0123.374460384384205160
Dunganese2/07602/0155.475390474474235185
Cyclops2/011602/0155.475390474474235185
Flustra3/017603/0195.776790587587275215
Lepas4/018604/0246.978560728728315245
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

 

Code Word
Phase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+
Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Size (kcmil)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLY
AAAC 6201 ALLOY REDUCED NEUTRAL MESSANGER
Artemia4145630.587111013513511590
Crab4745630.587111014314311590
Solaster2745448.6971760216216150120
Sandcrab1/0760277.4772800347347205160
Echinus1/0960277.4772800341341205160
Crayfish2/07/w60 mls2/0--72510485.8455.3235 Amps185 Amps
Sipho2/07/w60 mls2/0--72510485.8455.3235 Amps185 Amps
Fulgar3/017601/0123.374460519519275215
Arca4/018602/0155.475390643643315245
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

 
 

Code Word
Phase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+...............
Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLY
AAC NEUTRAL-MESSENGER
Haiotis67/w45 mls67563109.1101.685 Amps70 Amps
Patella6745675631031038570
Fusus47/w45 mls47881161.8151.7115 Amps90 Amps
Oyster47454788115415411590
Clam2745271350233233150120
Murex1/07601/071990374374205160
Purpura1/09601/071990368368205160
Nassa2/07602/072510462462235185
Melita3/017603/0193310562562275215
Portunus4/018604/0194020696696315245
Nannynose336.41980336.419614611181118420325
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

 

Code Word
Phase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+
Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLY
ASCR NEUTRAL-MESSENGER
Paludina614566/111901091098570
Voluta674566/111901141148670
Whelk414546/11860--16411590
Periwinkle474546/1186017217211590
Conch27601/06/14380420420205160
Neritina1/07601/06/14380420420205160
Cenia1/09601/06/14380414414205160
Runcina2/07602/06/15310520520235185
Triton2/011602/06/15310512512235185
Mursia3/017603/06/16620635635275215
Zuzara4/018604/06/18350789789315245
Limpet336.41980336.418/1868011671167420325
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

 

Code Word
Phase conductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+
Size (AWG)StrandingInsul. Thick. (mils)Size (AWG)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLY
ASCR REDUCED NEUTRAL-MESSENGER
Scallop414566/11190--14211590
Strombus474566/1119015115111590
Cockle274546/11190220220150120
Janthina1/076026/12853366366205160
Ranella1/096026/12853360360205160
Cavolinia2/076016/13550453453235185
Clio2/0116016/13550444444235185
Sanddollar3/019/w60 mls1/06/14380565552275 Amps215 Amps
Aega3/017601/06/14380549549275215
Cuttlefish4/019/w60 mls2/06/15310699684315 Amps245 Amps
Cerapus4/018602/06/15310681681315245
Cowery336.41980 mls336/418/1868012091167420 Amps325 Amps
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

There is a lot of debate still going on as to whether copper is better for electrical purposes or aluminum. If price was not a critical factor, most would suggest going in for silver as it is said to be the best conductor of electricity but has a low strength. However, when it comes to electrical wiring, price is a factor, as is efficiency.
Applications:
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene Insulation or 90°C maximum for crosslinked insulation.
Construction:
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR or 6201 alloy neutral messenger.
Standards:
B-230 Aluminum Wire 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.
There is a lot of debate still going on as to whether copper is better for electrical purposes or aluminum. If price was not a critical factor, most would suggest going in for silver as it is said to be the best conductor of electricity but has a low strength. However, when it comes to electrical wiring, price is a factor, as is efficiency.
You Might Also Like
Send your message to this supplier
Avatar
Ms. Carrey Guo
sales manager
*From:
To: Ms. Carrey Guo
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now