  • Model NO.: AAC
  • Conductor Type: Stranded
  • Conductor Material: Aluminum
  • Insulation Material: None
  • Range of Application: Overhead
  • Brand: Huatong
  • Voltage: High
  • Trademark: HT
  • Origin: China
  • Type: Bare
  • Application: Overhead, Industry
  • Sheath Material: None
  • Material Shape: Round Wire
  • Certification: ISO9001, CCC
  • Conductor: Aluminum
  • Delivery: 15 Days
  • Specification: aluminum
  • HS Code: 7614100000
Product Description
Aluminum Conductor AAC Cable/AAAC ACSR AAC Overhead Cable/All Aluminum AAC Conductor
1.Applications
ACSR,AAC,AAAC,ASCSR&ACAR conductor widely used in power transmission lines with various voltage levels. since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.

2. Specification:
 
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)

3.Service Performance
(1).The permissible long-time operating temperature for aerial conductor electronic cable is 70oC.
(2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.
(3).When connecting conductors,the AAC conductor electronic cable beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.
(4).Under installaion,the arc downing stress of all the conductors should be the same.With in the permissible distance of crossing buildings or dropping to the ground,the stress can be 10-15% higher than regular stress.
 
4.Material Standard:IEC83, IEC1089, 31, B232, BS215, DIN48204
 (1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182 
(2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel  wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied. 
(3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels
 
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. 
 
5.Technical details
 AAC Technical Characteristics Based on Standard DIN 48201 / DIN EN50182
  
Code numberAreaNumber of wiresWire     diameterConductor diameterLinear massRated strengthD.C. resistance at 20oC
mm2No.mmmmkg/kmkNΩ/km
1615.971.75.143.43.021.7986
2524.272.16.366.34.361.1787
3534.472.57.593.96.010.8317
5049.5739135.28.410.5776
5048.3191.89132.98.940.5944
7065.8192.110.5180.911.850.4367
9593.3192.512.5256.316.320.3081
120117192.814321.519.890.2456
150147.1372.2515.8405.726.480.196
185181.6372.517.5500.931.780.1588
240242.5612.2520.3671.143.660.1193
300299.4612.522.5828.552.40.0966
 
ACSR Technical Characteristics Based on Standard BS 215-2   
 
Code nameNominal aluminium areaStranding and wire     diameterSectional area of aluminiumTotal sectional areaApprox. overall diameterApprox. massCalculated D.C. resistance at 20oCCalculated breaking load
AlSteel
mm2No./mmmm2mm2mmkg/kmΩ/kmkN
RABBIT506/3.351/3.3552.8861.710.052140.542618.35
DOG1006/4.727/1.57105118.514.153940.273332.7
WOLF15030/2.597/2.59158.1194.918.137260.182869.2
DINGO15018/3.351/3.35158.7167.516.755060.181535.7
LYNX17530/2.797/2.79183.4226.219.538420.157679.8
ZEBRA40054/3.187/3.18428.9484.528.6216210.0674131.9
 
 
 AAAC Technical Characteristics Based on Standard BS 3242  
 
Code nameNominal aluminium areaStranding and wire     diameterSectional areaApprox. overall diameterApprox. massCalculated D.C. resistance at 20oCCalculated breaking load
mm2No./mmmm2mmkg/kmΩ/kmkN
ALMOND257/2.3430.17.02821.0948.44
CEDAR307/2.5435.477.62970.92819.94
FIR407/2.9547.848.851310.68813.4
HAZEL507/3.3059.879.91640.549816.8
OAK1007/4.65118.913.953250.276933.3
ASH15019/3.48180.717.44970.18350.65
ELM17519/3.7621118.85800.156859.1
UPAS30037/3.53362.124.719970.09155101.5